02.03.2013 Views

Scatterometer - Light Tec

Scatterometer - Light Tec

Scatterometer - Light Tec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

For 2D/3D scattered light measurements.<br />

A compact motorized optical system for scattering characterization of any kind of material.<br />

REFLET 90°<br />

REFLET Bench<br />

3D ( hemispheric)<br />

<strong>Scatterometer</strong><br />

COMPLETE SYSTEM<br />

DELIVERED<br />

IN A DARK BOX<br />

APPLICATIONS REFERENCES<br />

→ Photorealistic rendering: accurate measurement of spectral<br />

behaviour<br />

→ Optical sensors: medical, industrial , quality control,<br />

automotive<br />

→ Reflector material characterization for luminaries design<br />

→ Reflector material characterization for automotive<br />

headlamps design<br />

→ Cosmetics characteristics: spectral and specular behaviour<br />

→ Roughness controls in production<br />

→ Quality control of dust/particules in semiconductor<br />

→ LCD Backlighting<br />

→ Scattering of transmitting glasses<br />

→ Aerospace applications, measurements of black paints,<br />

BRDF of mirrors<br />

REFLET 180°<br />

°<br />

ADC, Alanod , Alcan , Almeco,<br />

Automotive- <strong>Light</strong>ing, AUO, , Arcelor,<br />

Bourget, Ball Aerospace , BARCO ,<br />

Chanel, Dupont , Entire, Essilor, Helbling,<br />

Hewlett Packard , Loepfe,<br />

STMicroelectronics , Procter&Gamble,<br />

PSA,<br />

University of Darmstadt, University of<br />

Madrid , Volkswagen,<br />

Espace Alexandra - 359 rue Saint Joseph - 83400 Hyères France<br />

Tel : +33 (0) 494 121 848 Fax : +33 (0) 494 121 849 E mail : sales@lighttec.fr web : www.lighttec.fr


REFLET is a compact, motorized optical system for scattering characterization of any kind of<br />

material and objects. It allows, in a fast and easy way, to measure luminous energy distribution, or<br />

spectral composition contained in the scattering lobes, and consequently characterizes surfaces of your<br />

examined regions such as roughness, defects, as well as types of coatings or paintings…<br />

Moreover, the system measures BRDF/BTDF which perfectly represents the way any surface scatters<br />

incoming light in 3D space.<br />

Diffuser<br />

The measurements are done in reflection and in transmission.<br />

The knowledge of the way light is reflected and transmitted trough a<br />

diffuser is very important for the use of this material in optical systems.<br />

Aluminum<br />

Reflector material can have quite<br />

complex behaviour depending on<br />

the plane of incidence . Reflet<br />

allows incidence parallel and<br />

perpendicular to stripes accurate<br />

measurements ( anisotropic<br />

material, polarization dependence)<br />

Ophthalmic glasses<br />

The knowledge of the scattering of<br />

specular surfaces (mirrors), transparent<br />

surfaces (glasses, lenses, crystals) with<br />

sometimes a very low scattering of 10 -9 ,<br />

is very difficult to measure without a<br />

high dynamic detection system, like the<br />

Reflet bench, which allows to measure<br />

BRDF of 10 -5 .<br />

Intensity [U.A]<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

-90<br />

-77<br />

1E+12<br />

1E+11<br />

1E+10<br />

1E+09<br />

1E+08<br />

1E+07<br />

100000<br />

0<br />

100000<br />

10000<br />

1000<br />

100<br />

10<br />

1<br />

0.01<br />

-64<br />

-51<br />

-38<br />

-25<br />

-12<br />

1<br />

Espace Alexandra - 359 rue Saint Joseph - 83400 Hyères France<br />

Tel : +33 (0) 494 121 848 Fax : +33 (0) 494 121 849 E mail : sales@lighttec.fr web : www.lighttec.fr<br />

14<br />

27<br />

40<br />

53<br />

66<br />

79<br />

Scattering curves of transparent lenses<br />

0 10 20 30 40 50 60 70 80 90<br />

0.1<br />

Diffusion Angle [deg]<br />

5°<br />

15°<br />

45°<br />

X<br />

Y<br />

Z


Cosmetics<br />

Cosmetic manufacturers needs to compare different chemical mixture to produce lipsticks or creams. REFLET<br />

allows to characterize this product on different skin and under different lighting ( different spectra)<br />

Illumination design software<br />

Illumination design software require accurate data to provide accurate simulations.Reflet provides 2D/3D<br />

BRDF or BTDF files to ready to be export to TRACEPRO, ASAP, LIGHTTOOLS or import in , LucidShape,<br />

PhotoPia or SPEOS.<br />

Realistic rendering software<br />

X<br />

Y<br />

Z<br />

In many industries including Automotive industry, interaction of light with materials is very important, in<br />

headlamps, tail lamps, dashboards, and the optical simulations made by designers, developers with their<br />

illumination design software, their realistic rendering software need scattering data to perform simulations and<br />

get results.<br />

Unfortunately, only theoretical data are available right now, and simulation results are not relevant of reality.<br />

It is why we have developed the REFLET Bench to answer all these problems.<br />

Espace Alexandra - 359 rue Saint Joseph - 83400 Hyères France<br />

Tel : +33 (0) 494 121 848 Fax : +33 (0) 494 121 849 E mail : sales@lighttec.fr web : www.lighttec.fr


ILLUMINATION<br />

<strong>Light</strong> Box o Halogen 100W light box<br />

o Option : 6-position filter wheel (color and ND filters)<br />

Spot size on the sample surface<br />

Beam aperture angle<br />

Goniometer<br />

TECHNICAL SPECIFICATIONS<br />

o Scattering configuration : Manually adjustable from Ø1 mm to Ø13 mm<br />

o Quasi-Specular configuration: Manually selectable Ø0.5mm Ø1mm Ø1.9mm<br />

o Scattering configuration : Manually adjustable from ±0.15° to ±2.26°<br />

o Quasi-Specular configuration: Manually selectable ±0.009° ±0.035° ±0.5°<br />

Standard Version<br />

REFLECTION MODE<br />

o 0°-90° motorized<br />

o Angular resolution: selectable ( 0.1°/1°/10° )<br />

o Positioning precision: 0.5°<br />

TRANSMISSION MODE<br />

o Fixed, θ=180°<br />

Optional upgraded version:<br />

o 0°-180° motorized (REFLECTION & TRANSMISSION)<br />

o Angular resolution: selectable ( 0.1°/1°/10° )<br />

o Positioning precision: 0.3°<br />

DETECTION<br />

Integrated-flux Detector • Visible channel : 400- 1000 nm, dynamic 10 4 or 10 9<br />

• Infra Red channel : 900- 1700 nm , dynamic 10 6<br />

Spectrograph (option) o Useful range: 420-900 nm or 900 – 1700 nm<br />

o Spectral resolution: selectable (0.6 nm/1 nm/5 nm/10 nm)<br />

Optical system o Scattering configuration :<br />

3 manually interchangeable optical blocs ( 2 to be chosen)<br />

Optical bloc 1 2 3<br />

Angular acceptance ± 2° ± 1.1° ± 0.04°<br />

Observed area size Ø14mm Ø8mm Ø6mm<br />

o Quasi-Specular configuration:<br />

Observed area size : Manually selectable Ø0.5mm Ø1mm Ø1.9mm<br />

Beam angle : Manually selectable ±0.009° ±0.035° ±0.5°<br />

Goniometer o θ: -90° to 90° motorized<br />

o φ: -90° to 90° motorized<br />

o Angular resolution: selectable ( 0.1° /1° /10° )<br />

o Positioning precision: 0.5°<br />

Polarizer/Analyzer set (option) o Rapid insertion<br />

o 0°-90° manual rotation<br />

MEASURING TIME<br />

180° θ-profile o “Integrated flux” mode: 45 s<br />

o “Spectrograph” mode: 10 s<br />

Espace Alexandra - 359 rue Saint Joseph - 83400 Hyères France<br />

Tel : +33 (0) 494 121 848 Fax : +33 (0) 494 121 849 E mail : sales@lighttec.fr web : www.lighttec.fr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!